25 Highlights 123 Differences 0 Reactions 0 Likes

KOHLER 38RCLC Facts: 146 Specifications & 25 Highlights

Before you hit “buy,” check out these 146 specs & features — including real-world favorites like general information, power & electrical output, engine & fuel system & performance & efficiency. It’s the kind of detail pros care about.

0 Points
KOHLER Generators
KOHLER Generators
KOHLER 38RCLC
KOHLER 38RCLC

Highlights 25

No extras. Just what matters.
0 Points

Why is KOHLER 38RCLC better than other generators ?

Power & Electrical Output

Scroll down for more facts

Engine & Fuel System

Scroll down for more facts

Dimensions & Weight

Scroll down for more facts

Durability & Build

Scroll down for more facts

Safety & Protection

Scroll down for more facts

Controls & Connectivity

Scroll down for more facts

Maintenance & Service

Scroll down for more facts

Environmental & Operating Conditions

Scroll down for more facts

Accessories & Packaging

Scroll down for more facts

Quick Take

The essentials that matter—nothing extra

A fast snapshot of the KOHLER 38RCLC, covering its standout specification and what you can expect right out of the box.

KOHLER 38RCLC
KOHLER 38RCLC

The KOHLER 38RCLC is a 38kW liquid-cooled powerhouse with a 1800 RPM industrial engine, offering consistent and quiet performance for large residential properties and a robust 100% one-step load acceptance capability.

Specifications & Facts 146

Specs measured. Drama avoided.

Not just numbers on a box. We looked at how the KOHLER 38RCLC actually performs with specs like general information, power & electrical output, engine & fuel system & performance & efficiency and others that users rely on daily.

General Information 12

KOHLER 38RCLC Phase Type

What phase type does it support?

0 KOHLER 38RCLC 0 Votes Single-Phase

generator in this range Who knows? (Help us out by suggesting one!)

Indicates whether the generator outputs single-phase or three-phase power.

KOHLER 38RCLC Country of Manufacture

Where is it made?

0 KOHLER 38RCLC 0 Votes USA

generator in this range Who knows? (Help us out by suggesting one!)

Indicates where the generator is manufactured.

KOHLER 38RCLC Product Type

What type of generator is this?

0 KOHLER 38RCLC 0 Votes Standby Generator

generator in this range Who knows? (Help us out by suggesting one!)

Identifies the general product classification of the generator.

KOHLER 38RCLC Generator Category

What category does this generator belong to?

0 KOHLER 38RCLC 0 Votes Residential

generator in this range Who knows? (Help us out by suggesting one!)

Defines the primary market segment the generator is designed for.

KOHLER 38RCLC Power Output Class

What is the power output class?

0 KOHLER 38RCLC 0 Votes High Power

generator in this range Who knows? (Help us out by suggesting one!)

Groups the generator based on its general power capacity range.

KOHLER 38RCLC Electrical Frequency

What is the electrical frequency?

60 Hz 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

Specifies the operating electrical frequency of the generator output.

Power & Electrical Output 15

KOHLER 38RCLC Running Wattage

What is the running wattage?

38,000 Watt 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Rated running power is 38000 Watt, representing the continuous electrical output available for loads.

Ensure connected loads do not exceed this value for sustained operation.

The continuous amount of power the generator can supply during normal operation without interruption.

KOHLER 38RCLC Starting Wattage

What is the starting wattage?

38,000 Watt 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Starting wattage is 38000 Watt, indicating the surge capacity available to start motors or large inductive loads.

Compare this with equipment inrush requirements when planning simultaneous starts.

The maximum surge power available to start appliances or equipment with high initial power demand.

KOHLER 38RCLC Amperage Output

What is the amperage output?

158 Amp 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Amperage output is 158 Amp, which defines the current available at rated voltage for connected loads.

At 240 V, this current level aligns with the generator's rated power and is useful for circuit planning.

Indicates the maximum current the generator can supply.

KOHLER 38RCLC Automatic Voltage Regulation

Does it regulate voltage automatically?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Yes means the unit includes automatic voltage regulation (AVR), which actively maintains output voltage within a tight range.

AVR protects connected electronics from voltage swings and improves compatibility with sensitive equipment.

Maintains consistent voltage under varying loads.

KOHLER 38RCLC Continuous Load Capacity

What continuous load can it handle?

100 % 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

The continuous load capacity is 100%, meaning the generator is rated to deliver its full rated output continuously without intentional derating.

This is suitable for sustained loads that match the generator's rating.

The percentage of load the generator can handle continuously.

KOHLER 38RCLC Surge Handling Capability

How much surge can it handle?

38,000 Watt 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Surge handling capability is 38000 Watt, showing the generator's ability to tolerate short-term load spikes.

This helps determine whether the unit can handle startup currents from compressors or pumps without tripping protections.

Describes how well the generator manages sudden power surges.

Engine & Fuel System 12

KOHLER 38RCLC Engine Brand Type

What engine brand type is used?

0 KOHLER 38RCLC 0 Votes OEM

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

The engine is supplied by OEM, indicating a factory-original engine designed or specified by the manufacturer.

This typically simplifies warranty support and ensures compatibility with factory service parts and procedures.

Indicates whether the engine is in-house or externally sourced.

KOHLER 38RCLC Oil Capacity

How much oil does it hold?

2.1 qt 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Oil capacity is 2.1 qt and 1.99 L, useful when preparing the correct lubricant volume for service.

Use the metric quantity if your replacement oil is measured in liters to avoid under- or over-filling.

Shows how much oil the engine requires.

KOHLER 38RCLC Fuel Type

What fuel does it use?

0 KOHLER 38RCLC 0 Votes Natural Gas, Propane

generator in this range Who knows? (Help us out by suggesting one!)

Specifies the type of fuel the generator operates on.

KOHLER 38RCLC Engine Type

What type of engine does it use?

0 KOHLER 38RCLC 0 Votes OHV

generator in this range Who knows? (Help us out by suggesting one!)

Defines the mechanical engine design used to generate power.

KOHLER 38RCLC Displacement

What is the engine displacement?

999 cc 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

Measures the engine’s cylinder volume, influencing power potential.

KOHLER 38RCLC Number of Cylinders

How many cylinders does it have?

0 KOHLER 38RCLC 0 Votes 2

generator in this range Who knows? (Help us out by suggesting one!)

States how many cylinders the engine has.

Performance & Efficiency 11

KOHLER 38RCLC Overload Recovery Time

How quickly does it recover from overload?

5 sec 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Overload recovery time is 5 sec, indicating how quickly the unit attempts to resume normal operation after an overload event.

Short recovery times reduce downtime but ensure protective devices and loads are compatible with this behavior.

Time required to recover normal output after overload.

KOHLER 38RCLC Cold Start Performance

How does it perform in cold starts?

0 KOHLER 38RCLC 0 Votes Enhanced

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Enhanced cold-start performance improves starting reliability in lower ambient temperatures and under adverse conditions.

This reduces the need for pre-heating accessories in typical cold-weather use.

Indicates ease of starting in low temperatures.

KOHLER 38RCLC Fuel Efficiency Rating

How fuel-efficient is the generator?

0 KOHLER 38RCLC 0 Votes Moderate

generator in this range Who knows? (Help us out by suggesting one!)

Overall assessment of how efficiently fuel is converted into power.

KOHLER 38RCLC Load Response Time

How fast does it respond to load changes?

10 sec 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

Time taken to stabilize output when load changes suddenly.

KOHLER 38RCLC Voltage Stability Under Load

How stable is voltage under load?

0 KOHLER 38RCLC 0 Votes Excellent

generator in this range Who knows? (Help us out by suggesting one!)

Indicates how well voltage remains steady under varying loads.

KOHLER 38RCLC Frequency Stability

How stable is the frequency output?

0 KOHLER 38RCLC 0 Votes Stable

generator in this range Who knows? (Help us out by suggesting one!)

Measures consistency of output frequency during operation.

Noise & Emissions 11

KOHLER 38RCLC Noise Level

What is the noise level of the generator?

52 dB 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

Measures the generator’s operating noise output in decibels, representing how loud the unit is during normal operation.

KOHLER 38RCLC Sound Insulation Type

What sound insulation is used?

0 KOHLER 38RCLC 0 Votes Full Enclosure

generator in this range Who knows? (Help us out by suggesting one!)

Describes built-in noise dampening materials or design.

KOHLER 38RCLC Muffler Type

What type of muffler does it have?

0 KOHLER 38RCLC 0 Votes Low-Noise

generator in this range Who knows? (Help us out by suggesting one!)

Identifies the exhaust muffler design.

KOHLER 38RCLC Emission Compliance

Is it emission compliant?

0 KOHLER 38RCLC 0 Votes EPA, CARB

generator in this range Who knows? (Help us out by suggesting one!)

Indicates regulatory emission standards met.

KOHLER 38RCLC Exhaust Orientation

Where is the exhaust directed?

0 KOHLER 38RCLC 0 Votes Rear

generator in this range Who knows? (Help us out by suggesting one!)

Shows the direction exhaust gases are expelled.

KOHLER 38RCLC Carbon Monoxide Detection

Does it detect carbon monoxide?

No 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Detects dangerous CO levels during operation.

Dimensions & Weight 11

KOHLER 38RCLC Width

What is the width of the generator?

32.4 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Overall width is 32.4 inch and 82.30 cm, helpful for siting the generator and ensuring adequate side clearance.

Use this when planning installation footprints or fitting through narrow access points.

Measures the overall width of the generator body.

KOHLER 38RCLC Depth

What is the depth of the generator?

51.2 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Overall depth is 51.2 inch and 130.05 cm, which affects placement depth and required clearance behind the unit.

Include this when designing enclosures or transport crating.

Measures the front-to-back depth of the generator.

KOHLER 38RCLC Height

What is the height of the generator?

33.9 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Overall height is 33.9 inch and 86.11 cm, providing a quick reference for clearance and installation planning.

Use these dimensions to check fit through doors, into enclosures, or under overhangs.

Measures the overall height of the generator.

KOHLER 38RCLC Weight

How much does the generator weigh?

630 lbs 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Unit weight is 630 lbs and 285.76 kg, important for transport, lifting equipment selection, and mounting considerations.

Confirm lifting points and handling procedures match the shown weight before moving the unit.

Indicates how heavy the generator is without fuel.

KOHLER 38RCLC Ground Clearance

What is the ground clearance?

3 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Ground clearance is 3 inch and 7.62 cm, which influences suitability for uneven surfaces and ease of draining or cleaning beneath the unit.

Lower clearance may require extra caution when siting on rough or obstructed surfaces.

Distance between the base and ground surface.

KOHLER 38RCLC Footprint Area

How much floor space does it need?

11.52 sq ft 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Footprint is 11.52 sq ft and 1.07 m², useful when allocating floor space and planning clearances.

Use the metric and imperial values to compare with site space requirements.

Total ground area occupied by the generator.

Durability & Build 12

KOHLER 38RCLC Structural Reinforcement

Does it have reinforced structure?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Yes indicates the unit has structural reinforcement to handle heavier mechanical stresses and improve durability.

Reinforcement helps reduce frame flex and component wear during transport and prolonged operation.

Extra bracing or reinforcement in the frame.

KOHLER 38RCLC Operating Life Expectancy

How long is its expected life?

20,000 hours 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Operating life expectancy is 20000 hours, reflecting the expected service life under normal maintenance and operating conditions.

Actual life will vary with operating profile, maintenance practices, and environmental factors.

Estimated total operational lifespan.

KOHLER 38RCLC Enclosure Type

Is it open or enclosed?

0 KOHLER 38RCLC 0 Votes Closed Frame

generator in this range Who knows? (Help us out by suggesting one!)

Describes whether components are exposed or enclosed.

KOHLER 38RCLC Vibration Isolation

Does it isolate vibration?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Reduces vibration transferred to the frame and ground.

KOHLER 38RCLC Frame Material

What is the frame made of?

0 KOHLER 38RCLC 0 Votes Aluminum

generator in this range Who knows? (Help us out by suggesting one!)

Specifies the primary structural material of the generator frame.

KOHLER 38RCLC Weather Resistance Rating

How weather-resistant is it?

0 KOHLER 38RCLC 0 Votes Weather-Resistant

generator in this range Who knows? (Help us out by suggesting one!)

Indicates protection against rain and moisture.

Safety & Protection 14

KOHLER 38RCLC Overload Protection

Does it have overload protection?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Yes indicates the generator has overload protection to interrupt or limit current when loads exceed safe thresholds.

Effective overload protection helps prevent equipment damage and maintains system safety.

Prevents damage by shutting down or limiting power during overload.

KOHLER 38RCLC Overvoltage Protection

Is there overvoltage protection?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Yes means the unit includes overvoltage protection to guard connected equipment against voltage spikes.

This protection reduces the risk of damage to sensitive electronics during transient electrical events.

Prevents excessive voltage from damaging devices.

KOHLER 38RCLC Spark Arrestor

Does it include a spark arrestor?

No 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

No spark arrestor is fitted, which means sparks may be emitted from the exhaust under certain conditions.

If operating in areas with fire-risk regulations or where spark arrestors are required, an aftermarket arrestor should be installed.

Prevents sparks from exiting the exhaust, reducing fire risk.

KOHLER 38RCLC Circuit Breaker Type

What type of circuit breaker does it use?

0 KOHLER 38RCLC 0 Votes Thermal-Magnetic

generator in this range Who knows? (Help us out by suggesting one!)

Identifies the type of circuit breaker used for electrical protection.

KOHLER 38RCLC Short Circuit Protection

Is short-circuit protection included?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Protects the generator from short-circuit conditions.

KOHLER 38RCLC Ground Fault Protection

Does it include ground fault protection?

No 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Reduces risk of electric shock by detecting ground faults.

Controls & Connectivity 12

KOHLER 38RCLC Control Panel Type

What type of control panel does it have?

0 KOHLER 38RCLC 0 Votes Digital

generator in this range Who knows? (Help us out by suggesting one!)

Describes the overall design of the control interface.

KOHLER 38RCLC Display Type

What type of display is included?

0 KOHLER 38RCLC 0 Votes LCD

generator in this range Who knows? (Help us out by suggesting one!)

Indicates the type of display used for monitoring.

KOHLER 38RCLC Display Information Shown

What information is shown on the display?

0 KOHLER 38RCLC 0 Votes Voltage, Frequency, Runtime

generator in this range Who knows? (Help us out by suggesting one!)

Lists data shown on the display screen.

KOHLER 38RCLC Control Interface

How do you control the generator?

0 KOHLER 38RCLC 0 Votes Buttons

generator in this range Who knows? (Help us out by suggesting one!)

Describes how users input commands.

KOHLER 38RCLC Remote Start Capability

Can it be started remotely?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Allows starting the generator from a distance.

KOHLER 38RCLC Smart App

Does it support a smart app?

No 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Enables monitoring and control through a mobile app.

Maintenance & Service 12

KOHLER 38RCLC Maintenance Indicator

Is there a maintenance indicator?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Yes indicates a maintenance indicator is present, helping operators know when routine service is due.

This feature simplifies upkeep scheduling and can prevent missed maintenance events.

Alerts the user when maintenance is required.

KOHLER 38RCLC Self-Diagnostic Capability

Does it have self-diagnostics?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Yes shows the unit offers self-diagnostic capability, which can report faults and simplify troubleshooting.

Self-diagnostics reduce downtime by quickly identifying likely failure modes for maintenance technicians.

Automatically detects and reports internal issues.

KOHLER 38RCLC Oil Change Interval

How often is oil changed?

200 hours 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

Number of operating hours between oil changes.

KOHLER 38RCLC Air Filter Type

What type of air filter does it use?

0 KOHLER 38RCLC 0 Votes Paper

generator in this range Who knows? (Help us out by suggesting one!)

Specifies the type of air filter used by the engine.

KOHLER 38RCLC Spark Plug Type

What type of spark plug does it use?

0 KOHLER 38RCLC 0 Votes Platinum

generator in this range Who knows? (Help us out by suggesting one!)

Specifies the type of spark plug required for proper engine ignition and performance.

Environmental & Operating Conditions 12

KOHLER 38RCLC Operating Temperature Range

What temperature range can it operate in?

0 KOHLER 38RCLC 0 Votes -20°F - 120°F

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

-20°F - 120°F corresponds to -28.9°C - 48.9°C, denoting the recommended operating ambient temperature window.

Operating beyond these limits may affect starting reliability, emissions, or component life.

Specifies the safe temperature range for operation.

KOHLER 38RCLC Storage Temperature Range

What is the storage temperature range?

0 KOHLER 38RCLC 0 Votes -30°F - 140°F

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

-30°F - 140°F corresponds to -34.4°C - 60.0°C, indicating the temperatures the unit can be stored in without damage.

Store within this range to avoid fluid, battery, or material degradation during long-term storage.

Defines safe temperatures for storage when not in use.

KOHLER 38RCLC Altitude Operating Range

What altitude can it operate at?

0 KOHLER 38RCLC 0 Votes Up to 5000 ft

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Up to 5000 ft is specified and corresponds to Up to 1,524 m; performance and power output are typically characterized up to this altitude.

Above this range, derating or special high-altitude configurations may be required.

Specifies supported operating elevations.

KOHLER 38RCLC Humidity Tolerance

How well does it handle humidity?

0 KOHLER 38RCLC 0 Votes High

generator in this range Who knows? (Help us out by suggesting one!)

Indicates tolerance to humid environments.

KOHLER 38RCLC Rain Operation Capability

Can it run in the rain?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Indicates if the generator can operate safely in rain.

KOHLER 38RCLC Dust Resistance Level

How dust-resistant is it?

0 KOHLER 38RCLC 0 Votes Medium

generator in this range Who knows? (Help us out by suggesting one!)

Describes protection against dust ingress.

Accessories & Packaging 12

KOHLER 38RCLC Packaging Width

What is the package width?

36 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Packaging width is 36 inch and 91.44 cm, important for freight planning and warehouse space allocation.

Include packaging dimensions when coordinating shipping or storage.

Width of the packaged box for shipping.

KOHLER 38RCLC Packaging Depth

What is the package depth?

55 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Packaging depth is 55 inch and 139.70 cm, relevant for freight dimensioning and storage planning.

Verify that shipping and storage areas can accommodate this packaged depth.

Depth of the packaged box for shipping.

KOHLER 38RCLC Packaging Height

What is the package height?

40 inch 0Votes

generator in this range Who knows? (Help us out by suggesting one!)

KOHLER 38RCLC
KOHLER 38RCLC

Packaging height is 40 inch and 101.60 cm, which is useful for storage space and shipping dimension planning.

Account for packaging size when arranging freight or warehouse storage.

Height of the packaged box for shipping.

KOHLER 38RCLC Wheel Kit

Is a wheel kit included?

No 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Indicates whether a wheel kit is included for mobility.

KOHLER 38RCLC Battery

Is the battery included?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Shows whether a starter battery is included.

KOHLER 38RCLC Oil

Is oil included?

Yes 0Votes KOHLER 38RCLC

generator in this range Who knows? (Help us out by suggesting one!)

Indicates whether engine oil is provided out of the box.

Surveys

Because hot takes deserve votes.

KOHLER 38RCLC Performance and Speed

How would you rate the performance and speed of this generator?

Very fast — Under 2 hours of runtime before needing a recharge 0Votes
Fast — 2 to 4 hours of runtime before needing a recharge 0Votes
Average speed — 4 to 6 hours of runtime before needing a recharge 0Votes
Slow — 6 to 10 hours of runtime before needing a recharge 0Votes
Very slow — Over 10 hours of runtime before needing a recharge 0Votes

KOHLER 38RCLC Durability and Longevity

How would you rate the durability and longevity of this generator?

Very durable — 10+ years of reliable performance with minimal maintenance 0Votes
Durable — 8 to 10 years of consistent performance 0Votes
Average durability — 5 to 7 years of service with regular maintenance 0Votes
Fragile — 2 to 4 years of performance before issues arise 0Votes
Very fragile — Less than 2 years of use before the generator starts malfunctioning 0Votes

KOHLER 38RCLC Ease of Setup

How easy is it to set up this generator?

Very easy — Plug-and-play, no tools required, ready to use in minutes 0Votes
Easy — Basic setup with minimal tools required, quick to get started 0Votes
Average — Setup requires some tools and time to get it running 0Votes
Difficult — Requires multiple steps and tools, setup time is longer 0Votes
Very difficult — Complex setup, professional help required to make it operational 0Votes

KOHLER 38RCLC Noise Level

How would you rate the noise level of this generator during operation?

Very quiet — Operating noise level under 50 dB, barely noticeable 0Votes
Quiet — Operating noise level between 51 to 60 dB, pleasant for use in quiet environments 0Votes
Average noise — Operating noise level between 61 to 70 dB, noticeable but tolerable 0Votes
Loud — Operating noise level between 71 to 80 dB, disruptive in residential areas 0Votes
Very loud — Operating noise level above 80 dB, unpleasant and disturbing 0Votes

KOHLER 38RCLC Design and Build Quality

How would you rate the design and build quality of this generator?

Very high quality — Premium materials and impeccable craftsmanship 0Votes
High quality — Solid construction with high-grade materials 0Votes
Average quality — Standard materials and construction, good value for money 0Votes
Low quality — Cheap materials, feels flimsy and prone to damage 0Votes
Very low quality — Poorly built with low-grade materials, unreliable 0Votes

KOHLER 38RCLC Fuel Efficiency

How fuel-efficient is this generator?

Very efficient — 10+ hours of operation per gallon of fuel 0Votes
Efficient — 7 to 9 hours of operation per gallon of fuel 0Votes
Average — 4 to 6 hours of operation per gallon of fuel 0Votes
Low efficiency — 2 to 3 hours of operation per gallon of fuel 0Votes
Very low efficiency — Less than 2 hours of operation per gallon of fuel 0Votes

KOHLER 38RCLC Ease of Use

How easy is it to operate this generator?

Very easy — Simple, user-friendly controls with intuitive operation 0Votes
Easy — Straightforward controls, easy to get the hang of 0Votes
Average — Some learning curve but manageable with the manual 0Votes
Difficult — Requires careful attention and reading of the manual 0Votes
Very difficult — Complicated controls, difficult to operate without expert help 0Votes

KOHLER 38RCLC Maintenance and Serviceability

How easy is it to maintain and service this generator?

Very easy — Minimal maintenance required, parts are easy to replace 0Votes
Easy — Occasional maintenance, but service instructions are clear 0Votes
Average — Regular maintenance required, parts are moderately accessible 0Votes
Difficult — Hard to access parts, maintenance takes time and effort 0Votes
Very difficult — Service parts are hard to find, frequent maintenance needed 0Votes

KOHLER 38RCLC Portability

How portable is this generator for outdoor use?

Very portable — Lightweight and compact, easy to transport 0Votes
Portable — Slightly bulky but manageable for one person to carry 0Votes
Average portability — Requires two people for transport, moderately heavy 0Votes
Difficult to transport — Large, heavy design, requires a vehicle for transport 0Votes
Very difficult to transport — Extremely bulky and heavy, difficult to move without assistance 0Votes

KOHLER 38RCLC Pricing

How would you rate the price of this generator?

Great value for money — Affordable for the features and quality offered 0Votes
Pretty good price — Reasonable pricing considering its performance and features 0Votes
Fair deal — Prices are fair but could be slightly better for the value 0Votes
Kinda pricey — A bit more expensive than expected for the features provided 0Votes
Crazy expensive — Overpriced for the features and performance offered 0Votes

Guides 1

Yes, we brought proof.

Files 1

KOHLER 38RCLC Installation Guide

kohler.com
kohler.com

Reviews 0

The good, the bad, and the brutally honest.

Average Rating

KOHLER Generators
KOHLER Generators
KOHLER 38RCLC
KOHLER 38RCLC
0 / 5 0 Reviews

Discussions 0

Thoughts, takes, and hot debates.

Awards 0

Only the best made it here.
Peep the Winners

Collections 0

Treasures You’ve picked. No fluff, all fun.

More Generators 9

Unlock more awesome finds.

Generators like KOHLER 38RCLC 1

Other KOHLER Generators Generators 8

KOHLER 38RCLC
KOHLER Generators
KOHLER Generators
KOHLER 38RCLC